Email Email
Home

Home

Contact us

Contact Us

Info

Store Info

View Cart

View Cart

Track Order

Track Order

Glossary

Glossary

Faq

Faq

HD-SDI Cameras and Recorders
Pan Tilt Zoom Cameras
Fixed Security Cameras
IP Security Cameras
Mega Pixel Security Cameras
Thermal Security Cameras
Digital Video Recorders
Network Video Recorders
Quads and Switchers
CCTV Monitors
CCTV Lenses
Housings and Mounts
Cable and Wire
Installation Accessories
Fiber Optic Products
Infrared Illuminators
Power Supplies
Audio Equipment
Access Control Products
IP Video Servers
Intercom Systems
New Hot Items
Door Controls
ACTi PDCX-1101 Indoor or Outdoor Smoke Fixed Dome Cover (4")
ADI-D55 3MP INDOOR DOME W/ D/N,IR,FIX LENS,DNR.POE,1080P/30FPS
ACI-B41
 
Leasing Application
Basics Of Video System Design
RMA Request Form
Lens Calculator
Voltage Drop Chart
Be the first to hear of sales and special offers, Join our email News Letter.
   
  Our Customers are saying...  
 
 
Let a customer service representative help you find what you're looking for.
Question Comments
Call Toll Free 1-888-376-2288
M-F 8am 5pm MST, or Email
 
  • Find us on Facebook
  • Home >> Cable and Wire >> Premise/Data Cables (Category 3, 5, 5E and 6)
    Premise/Data Cables (Category 3, 5, 5E and 6)

    Plenum
    Plenum
    Non-Plenum
    Non-Plenum

    What is Plenum Cable?Plenum cable is cable that is laid in the plenum spaces of buildings. The plenum (pronounced /ˈplɛnəm/) is the space that can facilitate air circulation for heating and air conditioning systems, by providing pathways for either heated/conditioned or return airflows. Space between the structural ceiling and the dropped ceiling or under a raised floor is typically considered plenum; however, some drop ceiling designs create a tight seal that does not allow for airflow and therefore may not be considered a plenum air-handling space. The plenum space is typically used to house the communication cables for the building's computer and telephone network; however, it has been proposed that the growing abandonment of cable in plenum spaces may pose a serious hazard in the event of a fire, as once the fire reaches the plenum space the airflow present in the space supplies fresh oxygen to the flame and makes it grow much stronger than it would have otherwise been. Recent testing by the American Society of Heating, Refrigerating and Air-Conditioning Engineers (ASHRAE) has shown that while flame spread is limited by accumulated cable bundles, other structural concerns may still exist due to increased load on suspended components. As plenum spaces are restricted from use as areas for storage, the principle behind removal of abandoned cable is that regulated removal prevents the use of plenum spaces as a storage area for abandoned cable. Additionally, no high-voltage powered equipment is allowed in the plenum space because presence of fresh air can greatly increase danger of rapid flame spreading should the equipment catch on fire.

    In the United States, plastics used in the construction of plenum cable are regulated under the National Fire Protection Association standard NFPA 90A: Standard for the Installation of Air Conditioning and Ventilating Systems. Plenum cable is jacketed with a fire retardant plastic jacket of either a low-smoke polyvinyl chloride (PVC) {patented 1987} or a fluorinated ethylene polymer (FEP). Polyolefin formulations, specifically based on polyethylene compounding had been developed by at least two companies in the early to mid-1990s; however, these were never commercialized and development efforts continue in these as yet untapped product potentials. Development efforts on a non-halogen plenum compound were announced in 2007 citing new flame retardant synergist packages that may provide an answer for an as yet under-developed plenum cable market outside the United States. All materials intended for use on wire and cables to be placed in plenum spaces are designed to meet rigorous fire safety test standards in accordance with NFPA 262 and outlined in NFPA 90A.

    Note that diligence is required to make sure that a non-plenum airspace stays that way. A non-plenum airspace can become a plenum airspace by accident if the ductwork is disconnected and not properly repaired and resealed. Ductwork disconnection can occur due to building damage such as earthquakes, aging or adverse environment causing the metal to corrode and fall apart, or simply negligence on the part of building contractors that leave work unfinished. In all such cases, discovery and repair of such problems to eliminate unintended plenums is difficult due to the hidden nature, limited space, and difficult access of most installed drop ceilings. For highest fire safety it is best to assume all drop-ceiling airspaces are plenums, whether or not they are officially designated as one.

    Cable which is to be run between floors in non-plenum areas is rated as riser cable. The fire requirements on riser cable are not as strict. Thus, plenum cable can always replace riser cable, but riser cable cannot replace plenum cable in plenum spaces. Cables like CAT 6 twisted-pair, coaxial cable, camera power cable and alarm cable are available in plenum and riser versions.
    Home | Contact Us | Store Info | View Cart | Track My Order | FAQ | Glossary of Terms | Sitemap | Tell a Friend
    © Copyright, camerasuperstore.com 2010. All Rights Reserved.
    Web-Stat
    Google
    WWW http://www.camerasuperstore.com/